Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 177 items found.

  • Transformer Tester

    Kvtester Electronics Technology Co.,Ltd

    High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • Insulation Resistance Tester For PV (Judge Deterioration Point)

    MIS-PVS - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester For PV (4 Range)

    MIS-PV2 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV2 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester for PV (2 range)

    MIS-PV1 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV1 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • GFCI and AC Circuit Analyzer

    Extech CT70-AC - Extech Instruments Corporation

    Circuit and wiring issues can introduce shock hazards (from grounding issues) and can compromise performance of machinery and equipment, from poor ground impedance, lack of sufficient voltage under load, and/or high ground-to-neutral voltage. The Extech CT70 is a GFCI and AC Circuit Analyzer which covers outlet load handling and outlet tester functions. Complete with an AC test cord (standard North American 3-prong plug).

  • HV Megmeter

    B-1013-6 - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation’s High Voltage Megmeter® series are unique battery powered DC hipot tester and meter. Models are available for withstand testing of insulation up to 50kV DC, as well as measuring leakage current as low as 0.001 microamp and resistance as high as 30 million megohms when testing underground cable, rubber safety gloves, vacuum interrupters, high voltage devices and all types of electrical insulation. All models have an over current trip feature to minimize arcing damage. Completely portable with rechargeable 12V battery which can be recharged from an automobile or 115V, 230V AC.

  • High Quality Transformer Oil Dielectric Strength Tester

    AS-023A - Chongqing Assen Power Equipment Co., Ltd

    AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).

  • Safety Enclosures

    SE - Xitron Technologies Inc.

    Safety First! Vitrek’s SE Series of high voltage safety enclosures are designed to prevent the potential of electrical shock when performing electrical tests. The enclosure comes standard with a magnetic safety interlock switch and chassis ground connection that must be wired from the safety tester to the safety enclosure by the end customer for safe operation.

  • Low Voltage Test & Measurement

    Greenlee Tools

    Low voltage testing is able to catch errors such as shorts and opens by applying current to a wire and measuring the voltage. The wire will have a current affected by several factors including resistance and components. If the wire is connected correctly, the test will read low resistance. That means current is flowing through the wire as expected and reaching the required connections. If the tester reads high resistance it means something is impeding the current from reaching its destination. This could be caused by a number of causes.

  • Battery Tester

    IT5100 Series - I-TECH Electronic Co., Ltd

    IT5100 series is a series of battery internal resistance testers with high precision, high resolution and high speed. IT5100 adopts AC 4-terminal sensing, that means the tester can test internal resistance and voltage simultaneously with high precision. Resistance resolution is down to 0.1 μΩ, voltage resolution is 10 μV.  Combined with external USB disk, IT5100 is available for long-term statistics calculation.Built-in comparator function, IT5100 can automatically determine whether the battery parameters meet the standards and count pass rate, which is suitable for a variety of battery`s test and pick. Built-in GPIB / USB / LAN communication interface to support SCPI communication protocol.Single unit of IT5102 support 16 channels batteries measurement, master- slave connection up to max.17 sets and extension channels quantity up to 272, that greatly improves testing efficiency. Built-in LAN / RS232 communication interface, IT5100 series can be widely applied in cellphone lithium batteries,electric vehicle batteries and other batteries inspection and sorting.

  • AC Hipot Tester /DC Hipot Tester

    YD-Series - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication

  • Surge / DC Hi-Pot Consoles

    HC Model - PJ Electronics, Inc.

    (Surge / Hi-Pot Consoles) - Now available in High Voltage models - 35,40 & 50KV. The HC Model offers Surge / DC Hi-Pot testing capabilities! The "HC" Model has all of the features of our "C" Model plus a DC Hi-Pot Tester. DC Hi-Pot includes dual LED panel meters that display direct read out of current and voltage, with overcurrent safety trip and the capability of ascertaining Polarization Index (PI) Test results.

  • 4 1/2 Digital Multimeter

    TH1941 - Shenzhen Chuangxin Instruments Co., Ltd.

    Digital multimeter TH1941 4 1/2-digit is voltage/current/resistance tester with multi functions and low cost. The instrument can stably perform measurement at high speed as several times as other instruments at the same level. It provides excellent performance, such as maximum reading of 21,000 counts, maximum DC voltage accuracy of 0.02%, and low cost to give you a best choice.

  • 4 1/2 Digit true RMS Digital Multimeter

    TH1941 - Changzhou Tonghui Electronic Co., Ltd.

    Digital multimeter TH1941 4 1/2-digit is voltage/current/resistance tester with multi functions and low cost. The instrument can stably perform measurement at high speed as several times as other instruments at the same level. It provides excellent performance, such as maximum reading of 21,000 counts, maximum DC voltage accuracy of 0.02%, and low cost to give you a best choice.

Get Help